91?清视频在线免费?看_99re6这里只有精品视频6_www.成人动漫_青青青青娱乐_小婕子伦流澡到高潮视频_亚洲综合AV永久无码精品一区二区

粉體行業在線展覽

產品

產品>

粉體測試設備>

光譜檢測分析儀

>飛秒瞬態吸收/拉曼光譜儀fs-TAS

飛秒瞬態吸收/拉曼光譜儀fs-TAS

直接聯系

天津東方科捷科技有限公司

美國

產品規格型號
參考報價:

面議

關注度:

1467

產品介紹

Transient Absorption Spectrometer (TAS)

可以同時獲取:飛秒瞬態吸收時間分辨光譜;飛秒瞬態拉曼光譜;

Our Transient Absorption Spectrometer (TAS) is a state-of-the-art instrument for femtosecond pump-probe spectroscopy. In an ultrafast time resolved experiment using TAS, a sample of interest is excited by an electronically resonant coherent femtosecond pulse referred to as the “pump.” This causes changes to the spectrum of the sample, which are monitored as a function of time by the white light supercontinuum probe, as sensed by the combination of a spectrograph and a camera or photodiode array.

  • Flexibly designed femtosecond pump-probe spectrometer

  • Supports a variety of ultrafast amplifiers & optical parametric amplifiers as input

  • Broad pump-probe delay range and high pump-probe delay resolution

  • Flexible imaging spectrograph supports automated switching of spectral range (detector) and resolution

  • Robust, stable device is factory assembled and aligned for easy integration

  • Worldwide installation and support is available

  • Many samples require a pump with wavelength different from that of the fundamental wavelength of the ultrafast laser. For this reason, TAS is often sold with an external optical parametric amplifier or harmonics generator. TAS is also offered with an addition of an internal second harmonic generation (SHG) option for the pump beam. The energy of the pump beam can be controlled internally by using a variable reflective neutral density filter imprinted on a thin glass substrate. This reduces the GVD introduced to the beam while allowing power control over a range of 0-4 OD. In order to reduce the effect of laser fluctuations, a TAS measurement is most typically performed at half the repetition rate of the laser using a New Focus phase locked optical chopper to block every other pump pulse. The spectrum of the transmitted or reflected white light supercontinuum probe is compared to the spectrum when the pump is present at half the repetition rate of the laser, the fastest rate possible, in order to minimize the effect of any laser noise and fluctuations on the end measurement.

The standard maximum optical delay between pump and probe in TAS is 3.3 ns. This is limited by the length of the stage (250 mm) and the number of optical passes that the probe beam makes to and from the high quality retroreflector used on the stage. In standard configurations, there are four passes (to and from the retroreflector twice). The resolution changes depending on the mode of operation. In the best case, the resolution is set by the minimal incremental motion (MIM) of the delay stage. This is applicable when performing a single measurement where the stage is incremented linearly in only one direction. In the standard TAS configuration, this is 13.3 fs. If many scans are to be averaged, the repeatability of positioning must be considered. If performing the same measurement, the uni-directional repeatability must be accounted for, which is also 13.3 fs in the standard TAS configuration. Lastly, if the set of time points is acquired randomly, as is often the case to minimize the effect of laser and sample changes to the measured dynamics, the bi-directional repeatability is the most important factor. For the standard TAS, this has a value of 26.6 fs. While the standard specifications are more than sufficient for most experiments, upgrades are available to increase the maximum optical delay and to reduce the minimum step size. The simplest, and most cost effective, upgrade is achieved by simply adding an additional retroreflector to the delay stage. There are then eight passes (to and from both reflectors twice) and the optical delay is increased to 6.67 ns. The unfortunate disadvantage of this configuration is that the resolution is also reduced by a factor of 2. For example, the MIM becomes 26.6 fs and the bidirectional repeatability becomes 53.2 fs, which is insufficient for some laser systems. To combat the resolution limits, it is possible to replace the linear stage and motion controller from the standard TAS configuration. With the ILS250HA stage and 2 retroreflectors, the optical delay is 6.67 ns, the MIM is 8 fs and the bidirectional repeatability is 18.6 fs. Alternatively, for the very best performance, the ILS300LM stage can be used with Newport’s XPS motion controller. This allows for optical delay up to 8 ns, MIM of 0.26 fs, and bidirectional repeatability of 8 fs. Additionally, the stage can move at up to 5 times higher speed than the standard TAS model and therefore random scans do not take as much time to perform.

產品咨詢

飛秒瞬態吸收/拉曼光譜儀fs-TAS

天津東方科捷科技有限公司

請填寫您的姓名:*

請填寫您的電話:*

請填寫您的郵箱:*

請填寫您的單位/公司名稱:*

請提出您的問題:*

您需要的服務:

發送

中國粉體網保護您的隱私權:請參閱 我們的保密政策 來了解您數據的處理以及您這方面享有的權利。 您繼續訪問我們的網站,表明您接受 我們的使用條款

飛秒瞬態吸收/拉曼光譜儀fs-TAS - 1467
天津東方科捷科技有限公司 的其他產品

FLOW

光譜檢測分析儀
相關搜索
關于我們
聯系我們
成為參展商

© 2025 版權所有 - 京ICP證050428號

主站蜘蛛池模板: 国产精品人人妻人人爽人人牛 | 久久视频这里只精品 | 色播影院性播影院私人影院 | 99国产精品 | 日韩午夜视频免费 | 日韩成人区 | 夜夜调教禁脔欢爱h | 成人网页 | www..com在线观看 | 亚洲网站观看 | 色吊丝永久网站 | 韩国av片女演员 | 欧美日韩无 | anquye在线观看 | 亚洲影院久久精品 | 精品国产人妻一区二区三区 | 久久久久久久久无码精品亚洲日韩 | 久久精品黄色 | 久久热这里只有精品在线观看 | 一级片黄色一级片 | 免费视频啪啪 | 久久99久 | 久久人人玩人妻潮喷内射人人 | 人人爽人人爽人人爽人人片av | 北条麻妃在线播放 | 中文字幕免费精品一区高清 | 免费aa大片 | 国产AV国片精品有毛 | 久久一区二区三区精华液介绍 | 影音先锋女人AV鲁色资源网久久 | 欧美视频在线观看 | 中午字幕无线码一区2020 | 午夜a级毛片免费观看 | 人禽大战视频免费 | 极品美女a诱v惑在线观看免费 | 免费人成无码大片在线观看 | 在线视频你懂 | 亚洲国产日韩在线一区模特 | 靠比视频免费观看 | 啊灬啊灬啊灬快灬深高潮了 | 久久三级影院 |